Optical Power Leveler KI5010-APC (1270~1330 nm, APC)
A combined power meter, variable optical attenuator and set-point controller that provides automatic power levelling in one single-direction or bi-directional fiber transmission line.
Fitted to a 35 mm DIN rail, and provided with a 12 - 48V power supply, this is an easy, reliable and unique solution to transmission problems caused by varying receiver power levels. This is typically useful to solve issues in SDN or "white box" type installations.
No telemetry link is required. Please enquire for alternative optical configurations and specifications.
General KI 5000 Optical Power Leveler specifications
Technology | Attenuator, power monitor & set-point control |
Output power set-point | -7 ~ -17 dBm (user adjustable) |
Output power stability | ± 0.3 dB (@ 1310 nm for KI5010) / (@1550 nm for KI5011) |
Output power setting resolution | 0.5 dB |
Attenuation range | 2 to 30 dB |
Operating wavelength | 1270~1330 nm (KI5010) / 1490~1610 nm (KI5011) |
Response time | < 1 sec |
Connector type | LC-PC Duplex or LC/APC (one fiber in, one fiber out) |
Input/output power handling | Single or bidirectional |
Fiber type | 9.5/125 um SMF (typical) |
ORL | Limited by LC/PC connectors |
PDL | 0.2 dB |
Max continuous power | 10 dBm |
Operating temperature | -40 ~ 65 degree C |
Relative humidity | 95% (non-condensing) |
Housing | Internally mounted 35 mm DIN rail |
MTBF | >100 Years @25 degree C (theoretical) |
Power supply | 12~48 Volt DC (on electrical power loss: pass-through mode) |
User controls | 2 up/down buttons, status indication, simple numeric display, USB for maintenance |
Size | 115 (D) x 98(H) x 22(W) mm |
Sales literature