Overview

This hand-held fiber optic variable attenuator is a precision handheld instrument commonly used for testing single mode fiber systems with an APC connector. Superior specifications, high productivity and remote-control capability also make this a genuine laboratory grade instrument. An additional typical application is as a passive adjustable attenuator pad in a transmission system.  

  • SM fiber, APC connector
  • Additional full-function optical power meter
  • Easy to use, accurate & productive
  • Excellent linearity & absolute accuracy
  • ISO/IEC 17025 traceable calibration 
  • Power handling to >+30 dBm / 1 Watt
  • Broadband, flat λ response
  • Low minimum insertion loss
  • Excellent ORL & PMD characteristics
  • SC, LC interchangeable connectors
  • Remote control (Labwindows) software
  • Modbus remote control protocol
  • Attenuation not affected by power on/off
  • Very long battery life

Key Features

Specifications

KI2010-INGAAS-APC specifications
Fiber type SMF-28, APC connector
 
Range 2.0 ~ 60.0 dB
 
Resolution 0.01 dB
 
Linearity / repeatability 0.03 dB
 
Absolute uncertainty 0.3 dB
 
Power capability +30 dBm
 
Optical return loss (ORL) 60 dB
 
Polarization dependent loss (PDL) < 0.1 dB
 
Thermal stability over temperature ±0.02 dB
 
Polarization mode dispersion (PMD) < 1 ps
 
Operating wavelength range 1200 ~ 1650 nm
 
Nominal calibration wavelengths 1310, 1550 nm
 
Wavelength dependence (1300 ~ 1625 nm) < ±0.25 dB up to 15 dB, < ±0.5 dB up to 20 dB
 
Wavelength dependence over DWDM4 S/C/L band (1490 ~ 1610 nm) < ±0.2 dB up to 15 dB, < ±0.3 dB up to 20 dB
 
OPM detector type InGaAs
 
OPM response wavelength 600 ~ 1700 nm
 
OPM calibration wavelengths 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
 
OPM power range +10 ~ -60 dBm (for 780 ~ 980 nm) / +10 ~ -70 dBm (for 1270 ~ 1650 nm)
 
OPM mid-range linearity 0.04 dB (typical)
 
OPM ID tone detection sensitivity Up to -50 dBm
 
OPM λ sensitivity, ± 30 nm. Selected λ 0.2 dB (typical)
 
Country of Origin Australia
 
Shipping Weight 1500 g
 
General Variable Optical Attenuator & Power Meter KI 2000 Series specifications
Interface USB-C
 
Power Battery / external power via USB-C. Jumper selectable charging
 
Battery types 2x AA (LR6) alkaline / 2x AA NiMH AA (rechargeable via USB-C)
 
Battery life Up to 1000 hours
 
Auto off User selectable
 
OPM resolution 0.01 dB
 
OPM calibration accuracy ±1 % (0.06 dB)
 
OPM tone detection 150 ~ 9999 Hz ± 1 %
 
OPM polarization sensitivity < 0.05 dB (typical)
 
OPM memory 1000 (4-λ tests) / unlimited on USB flash drive
 
Operating / storage temperature -15 to 55 °C / -25 to 70 °C
 
Relative humidity 0 ~ 95 %
 
Case Polycarbonate, 1-meter drop tested, with captive caps
 
IP rating IP52
 
Size 124 x 81 x 25 mm
 
Unit weight 0.45 kg
 
Calibration validity (ISO/IEC 17025) 3 years
 
Warranty 3 years
 

Documentation & Support

Applications

In the box

SC/SC Through Connector OPT046

SC-SC, Tough metal body, precision ceramic sleeve

LC Hybrid Connector Adapter OPT076

LC-SC Simplex. Tough metal body, precision ceramic sleeve

Wrist Strap / Lanyard

Handy lanyard & matching instrument attachment point

Quick Reference Guide QRG

Handy quick reference guide, some in multiple languages

Instrument User Manual

Comprehensive user manual, in well written English

Traceable Calibration Certificate ILAC/NATA Compliant

IEC/ISO 17025 compliant calibration certificate

Padded Canvas Carry Pouch OPT149

Soft pouch for two KI2000 series instruments. With carry straps and compartments for accessories storage.

Optional accessories

OPT051

FC Hybrid Connector Adapter OPT051

FC-SC. OPT081 adaptor is preferred for power meters, since FC ceramic sleeves can break easily. Tough metal body, precision ceramic sleeve

OPT080
OPT072

LC / F3000 Hybrid Connector Adapter OPT072

For F3000-SC PC Simplex. This is an LC-PC adapter that also fits F3000. For LC-PC only use, ceramic sleeve. OPT076 is better value and more robust.

OPT060G

E2000 Hybrid Connector Adapter Green OPT060G

E2000-SC, green, ceramic sleeve

OPT071

LSA-DIN47256 AVIM Hybrid Connector Adapter OPT071

AVIM / LSA / DIN47256 - SC. Ceramic sleeve

TOOL CLEAN-09A

Fiber Connector Cleaner Cartridge TOOL CLEAN-09A

To clean a connector end face / tip, prior to connector insertion into a mating adaptor.

TOOL CLEAN-03

Stick-Type Cleaner 2.5 mm TOOL CLEAN-03

To clean the end face and mating sleeve of a fiber optic connector with 2.5 mm diameter ferrule. SC, FC, ST etc.

TOOL CLEAN-04

Stick-type Cleaner 1.25 mm TOOL CLEAN-04

To clean the end face and mating sleeve of a fiber optic connector with 1.25 mm diameter ferrule, LC, SN etc

OPT153-CASE

Semi-Rigid Carry Case for Test Kits OPT153-CASE

Semi-rigid canvas test kit case for two KI2000 or KI7000 series instruments, and three KI9000 series instruments. With carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

OPT154B

Semi-Rigid Carry Case for Test Kits OPT154B

Semi-rigid canvas test kit case for two KI2000 series instruments, three KI900 series instruments, optical microscope & VFL pen. With cleaning materials, carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

OPT154B-CASE

Carry Case-only for Test Kits OPT154B-CASE

Semi-rigid canvas test kit case for two KI2000 series instruments, three KI900 series instruments, optical microscope & VFL pen. With carry straps and compartments for accessories storage. Moulded interior provides a perfect combination of durability, protection, and comfortable use.

© Kingfisher International, Australia, ABN 51 007 250 213