Overview

A Two-Way Optical Loss Test set (OLTS) that's perfect for medium to ultra high fiber count loss, length and optical return loss testing applications on single mode fiber with an APC connector at 1310 / 1550 nm. A pair of these compact instruments set new standards of productivity, accuracy and ease of use. The 650 nm VFL is on a separate port.

Each SM fiber needs just one test hook-up and one key press for a complete 2W / bidirectional loss length & ORL test, eliminating administration, training and test errors. Testing is accurate and can take only 5 seconds, direct onto flexible standards-compliant Tier 1 certification reports.

A pair of instruments both display length & bi-directional loss, & ORL each end, in real time, with no need to specify master/slave instruments. A single instrument can also be used as a stand-alone ultra-stable light source & power meter, VFL, ORL meter, or tone generator / detector. 

  • 25% of the size / weight, 7x the battery life of competitors 
  • Bidirectional Autotest loss, ORL & length testing on one fiber
  • Full-feature optical return loss tester
  • Real time Pass / Fail display
  • 8,000 fiber memory and USB key file dump
  • KITS™ reporting software
  • Autotest optical power meter, >25 λ, 1 % accuracy
  • Traceable reports: source stability & λ, meter cal & linearity, ORL cal
  • 80 hr alkaline battery life
  • 3 Year warranty and calibration cycle

Key Features

Specifications

KI23422OLF-INGAAS-APC specifications
Modulated output (source) 270 Hz, 1 kHz, 2 kHz ± 2 %, 12 Multi-Fiber ID tones
 
Output wavelength (source) 1310-1550 nm Laser APC, VisiTester APC
 
Output power (source) -3 dBm ±1 dB @ SMF
 
Adjust output power (source) Adjustable over 7 dB in 0.01 dB steps
 
Stability over temperature (source) 0.2 dB (max)
 
Short term stability for 15 min, typical ±2 °C, after warm up, ORL < -25 dB (source) 0.03 dB
 
Wavelength drift (source) 0.4 nm per °C (typical)
 
Wavelength initial tolerance @ 25 °C (source) 20 nm
 
Spectrum width @ FWHM (source) 3 nm (typical)
 
Reconnection repeatability @ 95% confidence (source) 0.1 dB
 
Length range (2-way Autotest only) 30 dB
 
Length accuracy (2-way Autotest only) 0.01% ± 4 meters
 
Length resolutions 1 meter (0.000~9.999 Km), 10 meters (10.00~99.99 Km), 100 meters (100.0~127.9 Km)
 
Loss range (2-way Autotest) 44 dB
 
Loss repeatability & loss linearity (2-way Autotest) 0.04 dB
 
Loss range (1-way Autotest) 44 dB
 
Loss repeatability & loss linearity (1-way Autotest) 0.04 dB
 
ORL range 0 ~ >60 dB
 
ORL port isolation > 60 dB
 
ORL accuracy 0.5 dB (@ 0 ~ 50 dB), 1 dB (@ 50 ~ 65 dB after zero offset)
 
ORL resolution 0.2 dB
 
VFL wavelength 650 ± 5 nm
 
VFL power 0 dBm ± 1 dB @ SMF
 
VFL laser safety Class 1, IEC60825-2
 
VFL blink rate (manual) CW or 2 Hz
 
General Two-Way Loss / Length / ORL Test Set KI 23400 Series specifications
Detector type (meter) InGaAs
 
Response wavelength (meter) 600 ~ 1700 nm
 
Calibration wavelengths (meter) 780, 820, 850, 980, 1270, 1290, 1300, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490, 1510, 1530, 1550, 1570, 1590, 1610, 1625, 1650 nm
 
Accuracy (meter) 1 % (0.06 dB)
 
Mid-range linearity (meter) 0.04 dB (typical)
 
Power range (meter) +10 ~ -60 dBm (780 ~ 980, 1590 ~ 1650 nm) / +10 ~ -70 dBm (1270 ~ 1650 nm)
 
Total uncertainty (meter) 0.3 dB (max)
 
Resolution (meter) 0.01 dB
 
Polarization sensitivity (meter) < 0.05 dB (typical)
 
ID tone detection & Autotest sensitivity (meter) Up to -50 dBm
 
Autotest: 1-way: compatible with other KI23400 & KI27400 models / 2-way: compatible with identical model only
 
Tone detection (meter) 150 ~ 9999 Hz ± 1 %
 
USB interfaces USB-micro for power & software / USB-A for memory key
 
Software KITS (free download)
 
Power Battery / External power via USB
 
Battery life Laser/LED source: 80 hours (typical) in Autotest, Power Meter: 1000 hours (typical)
 
Battery type 2x AA (LR6) Alkaline / 2x AA NiMH AA (rechargeable via USB)
 
Auto off Selectable
 
Display 74 mm x 55 mm high contrast LCD
 
Case Polycarbonate (body) / rubber (edges & corners), moisture resistance, 1-meter drop tested
 
Memory For 8,000 fibers / Unlimited on USB
 
Size 190 mm x 105 mm x 35 mm
 
Unit weight 0.42 kg
 
Shipping weight 1.5 Kg
 
Operating / storage temperature -15 to 55 °C / -25 to 70 °C
 
Relative humidity 0 ~ 95 %
 
Warranty 3 years
 
Calibration validity (ISO/IEC 17025) 3 years
 

Documentation & Support

Applications

In the box

OPT076

LC Hybrid Connector Adapter OPT076

LC Simplex, metal body.

OPT149

Padded Canvas Carry Pouch OPT149

Soft pouch with carry straps and compartments for accessories storage, able to carry 2x KI2000 series-size instruments.

OPT703

Low Reflection Terminator, SC/PC OPT703

Typically useful during ORL testing. Specification -55 dB, dependent on PC connector quality.

OPT704

Low Reflection Terminator, SC/APC OPT704

Typically useful during ORL testing, Specification -65 dB.

OPT730-SCP-SCA

OPT730-SCP-SCA

SMF SC/PC-SC/APC Lead, 2m, Simplex

Software (KITS)

Software (KITS)

Downloadable from Kingfisher's website for free.

Optional accessories

OPT051

FC Hybrid Connector Adaptor OPT051

FC. OPT081 is preferred for power meters, since FC ceramic sleeves break easily.

USD $19.96

In stock
Add to Cart
OPT072

LC / F3000 Hybrid Connector Adapter OPT072

For F3000 PC Simplex. This is an LC-PC adpater that also fits F3000. For LC-PC only use, OPT076 is better value and more robust.

USD $240.71

In stock
Add to Cart
OPT081

2.5 mm Universal Hybrid Connector Adapter OPT081

Universal 2.5 mm, including Duplex SC. Please observe application advice.

USD $94.53

In stock
Add to Cart
OPT084

1.25 mm Universal Hybrid Connector Adapter OPT084

Universal 1.25 mm, including simplex LC. Please observe application advice.

USD $143.21

In stock
Add to Cart
OPT085

1.25 mm Universal Hybrid Connector Adaptor OPT085

Universal 1.25 mm. Also fits: Duplex LC, Senko CS, SN duplex, and USconec MDC duplex connectors. Please observe application advice.

USD $165.05

In stock
Add to Cart
OPT153-CASE

Semi-Rigid Carry Case for Test Kits OPT153-CASE

Canvas case with foam compartments for 2x KI2000 or KI7000 series instrument, 3x KI9000 series instrument and other accessories.

USD $285.84

In stock
Add to Cart
OPT154B

Semi-Rigid Carry Case for Test Kits OPT154B

Content: 1x Case (OPT154B-CASE) (suitable for 2x KI2000 series instrument, 1x Microscope, 1x VFL, Accessories); 5x 2.5mm Fiber Conn Cleaning Sticks; 5x 1.25mm Fiber Conn Cleaning Sticks; 1x Blower Brush (TOOL CLEAN-01A); 1x Fiber Conn Cleaning Cartridge(TOOL CLEAN-09A).

USD $425.54

In stock
Add to Cart